Working environment to use device programmer is very important to fully utilize the performance. Poor environment can cause programming problem. Please read and follow our instructions as follows.
Working enviroment to use device programmer is very import to fully utilize the performance. Poor enviroment can cause programming problem. Please read and follow our instructions as follows.
Please make sure that the programmer becomes stand-by after turning on the power and self-test is completed sucessfully.
If selftest can not be completed sucessfully, please turn off the power and check the following.
Please do not set adaptors and IC on the device programmer when the power is turned on.
If the error still occurs after rebooting of the device programmer, pleae do not turn off the power and check the status of LED, error message and any other message on the display.
It is not a part of warranty since socket adaptor is consumable item. Generally speaking, mechanical life of IC socket is approximately 10,000 times of open/close. Therefore, the mechanical life of socket usually ends
After handling 5,000 pieces of IC (open/close). The actual life of socket varies by the working environments. If the contact error is frequently observed, we recommend changing the socket adaptor.
Please make sure that the programmer becomes stand-by after turning on the power and self-test is completed sucessfully.
If selftest can not be completed sucessfully, please turn off the power and check the following.
Please do not set adaptors and IC on the device programmer when the power is turned on.
If the error still occurs after rebooting of the device programmer, pleae do not turn off the power and check the status of LED, error message and any other message on the display.
Lead free IC use harder leads and balls. Therefore, it is harder to make a contact breakng through the oxidized tin overing up balls and leads. Please be aware of this situation.
Lead Free
Leaded IC had softer balls or leads. It was easier for contact to break though the oxidized tin since the surface of ball or leas is easier to be dent with lower pressure.
According to the report of IC supplier, the life of socket to be used on Pb free IC can be 10 times shorter than that of leaded IC.
Contact Failure
Gold coated contact of IC socket may accumulate oxidized tin which is transferred from the leads (balls) of IC. As the number of socket useage is increased, oxidized tin is accumulated causing contact failure. Then contact faiure cause programing error.
IC Socket
Minato use socket recommended by IC supplier. Recently the contact pressure tends to be lower to avoid dents on balls (leads).
(*)If contact pressure is too low, oxidized tin covering up balls (leads) can not be broken thorugh causing contact failure. Then it cause frequent programming error.
Remedy : Cleaning of IC Socket
If you start to observe contact failure and lowered yeild rate, please purchase new socket adaptors or clean the socket.
For cleaning, please contact to our authorized distirbutor or to your sales rep from Minato Holdings Inc.
Daily check and annual calibration (once or twice a year) is recommended on device programmer since it is a production or development equipment.
We maintain maintenance spare parts untill five years after the discontinuance of the device programmer.
After the five years of the discontinuance, we may not keep the socket of sapre parts of the particular model so that we might not be able to offer the mainenance support.
However, most of minor repair which is major part of our maintenance can be still offerred after five years of the discontinuance of the device programmer. Please contact to Minato for detail.
Please prepare the following inf. before contacting us; Model # of the device programmer, date of purchase, name of the distributor, serial number.